DIGGA PREMIUM DRIVES
5 YEAR WARRANTY
Only we give you 5 year warranty for Digga Premium Drive Augers.
SERIA PREMIUM DRIVE
Would you like to get some information about Premium Drive augers?
NUMBER ONE
Digga’s company is manufacturer of the best planetary gears, made for auger drives.
OD 1 DO 6 TON
• mini loaders
• mini-excavators
• small backhoe loaders
• cranes
• drilling equipment
PREMIUM DRIVE
• PDD
• PDX2
• PD 3
• PD 4
• PD 5
OD 4 DO 11 TON
• midi-excavators
• backhoe loaders
• small bucket-wheel excavators
• cranes
• telescope loaders
PREMIUM DRIVE
• PD 6
• PD 6HF
• PD 7
• PD 8
• PD 10
• PD 10HF
OD 12 DO 24 TON
• piling and drilling equipment
PREMIUM DRIVE
• PD 12
• PD 15
• PD 18
• PD 22
OD 24 DO 50 TON
• piling and drilling equipment
PREMIUM DRIVE
• PD 25
• PD 30
• PD 40
• PD 50
DIGGA PDD
Technical data
SPECIFICATION | PDD |
Recommended Flow | 50-150 lpm |
Max Torque | 1171 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 60 lpm |
Max Flow - Do not exceed | 95 lpm @ 160 bar |
Max Power - Do not exceed | 25 Kw (34 hp) |
Overall Length | 500 mm |
Diameter | 187 mm |
Weight (no frame / hitch) | 41 Kg |
Std Output Shaft | 65 mm Round |
Swing Control | N / A |
Diggalign | N / A |
Rec Auger | A4 |
Max Auger Dia Clay / Shale | 400 mm |
Max Auger Dia Earth | 500 mm |
DIGGA PX2
Technical data
SPECIFICATION | PDX2 |
Recommended Flow | 30-50 lpm |
Max Torque | 1743 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 60 lpm |
Max Flow - Do not exceed | 115 lpm @ 130 bar |
Max Power - Do not exceed | 25 Kw (34 hp) |
Overall Length | 557 mm |
Diameter | 187 mm |
Weight (no frame / hitch) | 45 Kg |
Std Output Shaft | 65 mm Round |
Swing Control | N / A |
Diggalign | N / A |
Rec Auger | A4 |
Max Auger Dia Clay / Shale | 450 mm |
Max Auger Dia Earth | 600 mm |
DIGGA PD 3
Technical data
SPECIFICATION | PD3 |
Rec Flow Range | 45-75 lpm |
Max Torque | 3544 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure | Do not exceed 240 bar @ 60 lpm |
Max Flow | Do not exceed 115 lpm @130 bar |
Max Power | Do not exceed 25 Kw (34 hp) |
Overall Length | 579 mm |
Diameter | 240 mm |
Weight (no frame / hitch) | 56 Kg |
Std Output Shaft | 65 mm Round |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A4 |
Max Auger Dia Clay / Shale | 600 mm |
Max Auger Dia Earth | 750 mm |
DIGGA PD 4
Technical data
SPECIFICATION | PD4 |
Rec Flow Range | 55-85 lpm |
Max Torque | 4448 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure | Do not exceed 240 bar @ 60 lpm |
Max Flow | Do not exceed 115 lpm @130 bar |
Max Power | Do not exceed 25 Kw (34 hp) |
Overall Length | 579 mm |
Diameter | 240 mm |
Weight (no frame / hitch) | 56 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A4 / AGS A6 / A7 |
Max Auger Dia Clay / Shale | 750 mm |
Max Auger Dia Earth | 900 mm |
DIGGA PD 4 High Flow
Technical data
SPECIFICATION | PD4HF |
Rec Flow Range | 50-150 lpm |
Max Torque | 4473 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 130 lpm |
Max Flow - Do not exceed | 170 lpm @ 180 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 950 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 149 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A6 / A7 |
Max Auger Dia Clay / Shale | 750 mm |
Max Auger Dia Earth | 1000 mm |
DIGGA PD 5
Technical data
SPECIFICATION | PD5 |
Rec Flow Range | 60-95 lpm |
Max Torque | 5151 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure | Do not exceed 240 bar @ 60 lpm |
Max Flow | Do not exceed 115 lpm @130 bar |
Max Power | Do not exceed 25 Kw (34 hp) |
Overall Length | 579 mm |
Diameter | 240 mm |
Weight (no frame / hitch) | 56 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | AGS / A6 / A7 |
Max Auger Dia Clay / Shale | 900 mm |
Max Auger Dia Earth | 1000 mm |
DIGGA PD 6
Technical data
SPECIFICATION | PD6 |
Rec Flow Range | 70-115 lpm |
Max Torque | 5596 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure | Do not exceed 240 bar @ 60 lpm |
Max Flow | Do not exceed 115 lpm @130 bar |
Max Power | Do not exceed 25 Kw (34 hp) |
Overall Length | 730 mm |
Diameter | 240 mm |
Weight (no frame / hitch) | 56 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | AGS / A6 / A7 |
Max Auger Dia Clay / Shale | 900 mm |
Max Auger Dia Earth | 1000 mm |
DIGGA PD 6 High Flow
Technical data
Specyfikacja techniczna | PD6HF |
Rekomendowany zakres przepływu | 60-150 lpm |
Maks. moment obrotowy | 5634 Nm |
Silnik hydrauliczny | 6K Bell EATON |
Zawór ciśnienia | tak |
Zawór kontroli energii | opcja |
Linia przelewowa | nie |
Ciśnienie maks.- nie przekraczać! | 240 bar @ 130 lpm |
Przepływ maksymalny- nie przekraczać! | 210 lpm @ 145 bar |
Moc maks.- nie przekraczać! | 50 Kw (67 hp) |
Całkowita długość | 950 mm |
Średnica | 290 mm |
Waga (bez ramy i mocowania) | 149 Kg |
Standardowy trzon napędowy | 75 mm kwadratowy |
Kontrola wahania | opcja |
System Diggalign | opcja |
Rekomendowane wiertło | A6 / A7 |
Maks. średnica wiertła dla gliny/łupek | 900 mm |
Maks. średnica wiertła dla ziemii | 1200 mm |
DIGGA PD 7
Technical data
SPECIFICATION | PD7 |
Rec Flow Range | 75-115 lpm |
Nominal Torque | 6040 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 60 lpm |
Max Flow - Do not exceed | 115 lpm @ 130 bar |
Max Power - Do not exceed | 25 Kw (34 hp) |
Overall Length | 734 mm |
Diameter | 240 mm |
Weight (no frame / hitch) | 100 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | AGS / A6 / A7 |
Max Auger Dia Clay / Shale | 900 mm |
Max Auger Dia Earth | 1000 mm |
DIGGA PD 8
Technical data
SPECIFICATION | PD8 |
Rec Flow Range | 80-115 lpm |
Nominal Torque | 7024 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure - Do not exceed | Do not exceed 240 bar @ 60 lpm |
Max Flow - Do not exceed | Do not exceed 115 lpm @ 130 bar |
Max Power - Do not exceed | Do not exceed 25 Kw (34 hp) |
Overall Length | 854 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 107 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A6 / A7 |
Max Auger Dia Clay / Shale | 1000 mm |
Max Auger Dia Earth | 1200 mm |
DIGGA PD 8 High Flow
Technical data
SPECIFICATION | PD8HF |
Rec Flow Range | 80-200 lpm |
Nominal Torque | 7136 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 130 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 950 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 149 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A6 / A7 |
Max Auger Dia Clay / Shale | 1000 mm |
Max Auger Dia Earth | 1200 mm |
DIGGA PD 10
Technical data
SPECIFICATION | PD10 |
Rec Flow Range | 85-115 lpm |
Nominal Torque | 8487 Nm |
Motor | 2K Bell EATON |
Pressure Valve Fitted | Optional |
Energy Control Valve | N / A |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 60 lpm |
Max Flow - Do not exceed | 115 lpm @ 130 bar |
Max Power - Do not exceed | 25 Kw (34 hp) |
Overall Length | 854 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 110 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A6 / A7 |
Max Auger Dia Clay / Shale | 1000 mm |
Max Auger Dia Earth | 1500 mm |
DIGGA PD 10 High Flow
Technical data
SPECIFICATION | PD10HF |
Rec Flow Range | 100-200 lpm |
Nominal Torque | 9690 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 130 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 950 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 149 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A8 / A9 |
Max Auger Dia Clay / Shale | 1000 mm |
Max Auger Dia Earth | 1500 mm |
DIGGA PD 12
Technical data
SPECIFICATION | PD12 |
Rec Flow Range | 120-230 lpm |
Max Torque | 11268 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 950 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 149 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A8 / A9 |
Max Auger Dia Clay / Shale | 1200 mm |
Max Auger Dia Earth | 1600 mm |
DIGGA PD 15
Technical data
SPECIFICATION | PD15 |
Rec Flow Range | 120-230 lpm |
Max Torque | 13897 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 210 lpm @ 145 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 1006 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 176 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A8 / A9 |
Max Auger Dia Clay / Shale | 1200 mm |
Max Auger Dia Earth | 1600 mm |
DIGGA PD 18
Technical data
SPECIFICATION | PD18 |
Rec Flow Range | 120-230 lpm |
Max Torque | 17603 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 1006 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 176 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A8 / A9 |
Max Auger Dia Clay / Shale | 1500 mm |
Max Auger Dia Earth | 1600 mm |
DIGGA PD 22
Technical data
SPECIFICATION | PD22 |
Rec Flow Range | 120-230 lpm |
Max Torque | 22142 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 1006 mm |
Diameter | 290 mm |
Weight (no frame / hitch) | 176 Kg |
Std Output Shaft | 75 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A8 / A9 |
Max Auger Dia Clay / Shale | 1500 mm |
Max Auger Dia Earth | 1600 mm |
DIGGA PD 25
Technical data
SPECIFICATION | PD25 |
Rec Flow Range | 120-230 lpm |
Max Torque | 26267 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 1152 mm |
Diameter | 355 mm |
Weight (no frame / hitch) | 300 Kg |
Std Output Shaft | 100 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A10 / A11 |
Max Auger Dia Clay / Shale | 1200 mm |
Max Auger Dia Earth | 1600 mm |
DIGGA PD 30
Technical data
SPECIFICATION | PD30 |
Rec Flow Range | 120-230 lpm |
Max Torque | 30543 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 1152 mm |
Diameter | 355 mm |
Weight (no frame / hitch) | 300 Kg |
Std Output Shaft | 100 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A10 / A11 |
Max Auger Dia Clay / Shale | 1200 mm |
Max Auger Dia Earth | 1600 mm |
DIGGA PD 40
Technical data
SPECIFICATION | PD40 |
Rec Flow Range | 120-230 lpm |
Max Torque | 33041 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 1152 mm |
Diameter | 355 mm |
Weight (no frame / hitch) | 300 Kg |
Std Output Shaft | 100 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A10 / A11 |
Max Auger Dia Clay / Shale | 1500 mm |
Max Auger Dia Earth | 1800 mm |
DIGGA PD 50
Technical data
SPECIFICATION | PD50 |
Rec Flow Range | 120-230 lpm |
Max Torque | 38420 Nm |
Motor | 6K Bell EATON |
Pressure Valve Fitted | Included |
Energy Control Valve | Optional |
Case Drain Required | No |
Max Pressure - Do not exceed | 240 bar @ 140 lpm |
Max Flow - Do not exceed | 230 lpm @ 130 bar |
Max Power - Do not exceed | 50 Kw (67 hp) |
Overall Length | 1152 mm |
Diameter | 355 mm |
Weight (no frame / hitch) | 300 Kg |
Std Output Shaft | 100 mm Square |
Swing Control | Optional |
Diggalign | Optional |
Rec Auger | A10 / A11 |
Max Auger Dia Clay / Shale | 1500 mm |
Max Auger Dia Earth | 1800 mm |